CALCULATION SERIES OF 23 AND 24 NOVEMBER 2026
All physical times and spatial field coordinates in the FSI runs use model SI units. The concrete replay and its stress history use prototype SI units. Raw SU2 directories, full native VTK snapshots, restarts and OOFEM integration-point output are retained in the project working archive. The current spatial record comes from segment-series. Every time in the figures uses SU2's configuration convention Time_Iter multiplied by the physical step. The initial label zero includes an implicit flow update. In the segment/section the load multiplier is zero at this label.

For the limited fixed controls the figure uses a common physical window. G200, G140, G100 and G070 use grades 2.0, 1.4, 1.0 and 0.7. Aerodynamic force in the history equals 2.02014 N times the native Cartesian coefficient. In 2D the numerical force is for a one-metre strip. Section lift is along +y and positive pitch is about +z. In the 3D configuration use CFy to recover vertical force. The native CL follows the solver wind-axis convention and need not be vertical for this coordinate system.

For each case, run_inputs holds the overrides read by SU2. Material indices in element_properties.dat and its structural-zone alias element_properties_1.dat must be identical. The plane sections use models/refinement/G200/2D or G140/2D with the same calibrated insert modulus. The G140 override files are in run_inputs/plane-G140. The spatial pilot is in results/segment-pilot. The more refined initial check uses models/segment_coarse. The raw H restart and zone meshes remain in the associated case folder. Output arrays with invalid setup or poor numerical behavior were excluded from the figures. See run_catalog.csv.

The command sequence for the local material handoff is replay.py, followed by local_inertia.py. replay.py independently checks the 3D segment structural equilibrium, registers the patch, writes prototype forcing and invokes the bundled OOFEM 3.0 executable. The registration table integrates the slab contact with the floor beam separately from pressure and skin friction on exposed areas. The stress used on the beam side is recovered from its own linear TET4 displacement gradient. Boundary work uses segment-to-patch quadrature and trapezoidal force in time. Inertia sensitivity is checked with an independent linear patch solver. Section histories use section_history.py. Figures and fixed-body spectra use summarize_runs.py, segment_trace.py and spatial_fields.py. Files in the benchmark directory identify the precise raw frames used. The specified convergence thresholds in Table 8 govern interpretation.

Reproduction from the unpacked study root (Python packages include NumPy, SciPy, Matplotlib and Shapely).
1. Run results/dry_modes.py and results/dry_decay.py. The first writes modal displacement arrays into work for results/modal_comparison.py.
2. Run results/quadratic_modes.py with "results/segment-pilot results/pilot-TET10-modes.csv" and then "models/segment_coarse results/coarse-TET10-modes.csv" as its two positional parameters. Run results/modal_comparison.py to compare the linear-tetrahedron shapes on common quadrature points.
3. Use the SU2 configurations under results/run_inputs/<case> together with the corresponding zone meshes and element property files described above. Launch SU2_CFD from the case directory with the master config.cfg, or fixed_flow.cfg for a stationary single zone. The job metadata contains the exact physical step count and OpenMP thread count.
4. Use results/replay.py <raw-case> <model-directory> <registration-file> <output-directory> --oofem <OOFEM-root>. The medium registration is in results/qa/medium-transfer.npz and the full-resolution registration in models/damage/segment_transfer.npz. Replay expects per-step native volume fields. The output includes an element-level damage trace. Run results/local_inertia.py <output-directory> for the dynamic reference.
5. Use results/section_history.py, results/wind_sweep.py, results/segment_trace.py and results/wake_probes.py to recover the reported signals. Each executable Python script accepts --help where positional paths are required. The snapshot photos and films are derived exclusively from native numerical fields. All deformation amplification in a film is labeled.

Native solver SHA-256
SU2_CFD.exe 01f22d0c9de2e9a5feea666f67adf3957f503d2e14ca6fd998a9a28a11417bf7
oofem.exe 0de2eb8c7fb3e011491d0438f229a3f33de5870781a6137354089289a98507e3