Reverse-order partition (membrane factor first), shares in % of the deficit
  gradient     reference                 act  mem  ->  act  mem   residual (both orders)
  SW/RW        conductivity-equivalent  17.2 10.0 -> 16.5 10.7   72.8 / 72.8
  SW/RW        composition              11.4  8.0 -> 11.0  8.4   80.6 / 80.6
  RO-brine/RW  conductivity-equivalent  14.9 17.8 -> 13.7 19.0   67.3 / 67.3
  RO-brine/RW  composition              10.3 14.8 ->  9.5 15.6   74.9 / 74.9
  largest change of an individual share: 1.19 percentage points
SW/RW: ideal ln ratio differs between references by 0.996; activity correction ln(gH/gL) = -0.338
RO-brine/RW: ideal ln ratio differs between references by 1.074; activity correction ln(gH/gL) = -0.361
molal instead of molar Na-Cl ratio, SW/RW (conductivity-equivalent reference): driving force changes by 0.20 %
molal instead of molar Na-Cl ratio, SW/RW (composition reference): driving force changes by 0.17 %
molal instead of molar Na-Cl ratio, RO-brine/RW (conductivity-equivalent reference): driving force changes by 0.36 %
molal instead of molar Na-Cl ratio, RO-brine/RW (composition reference): driving force changes by 0.30 %
Calculation sequence (SI Table S4)
  gradient     reference                ln(ideal)  ln(gH/gL)  corrected  f_act%  alpha  (1-f)alpha  Emeas/Eideal
  SW/RW        conductivity-equivalent     5.233    -0.338     4.896    6.45   0.96      0.898      0.625
  SW/RW        composition                 6.230    -0.338     5.892    5.42   0.96      0.908      0.525
  RO-brine/RW  conductivity-equivalent     5.762    -0.361     5.401    6.26   0.92      0.862      0.579
  RO-brine/RW  composition                 6.835    -0.361     6.475    5.28   0.92      0.871      0.488
+/-0.01 in Emeas/Eideal shifts the residual by 0.4-0.8 percentage points
ideal half-pair voltage SW/RW with activity correction (conductivity-equivalent): 0.126 V
ideal half-pair voltage SW/RW with activity correction (composition): 0.151 V